欢迎访问宝典图库网站!

专注生产工业用超声波清洗机

让工业清洗无难事

电话

业务咨询电话:

18663767799

宝典图库
你所在位置: 首页-新闻动态-常见问题高压去毛刺清洗机运行前后的各个问题排查
常见问题

高压去毛刺清洗机运行前后的各个问题排查

作者:admin来源:/时间:2022-12-02

高压去毛刺清洗机因为是使用高压水柱清理污垢,所以高压去毛刺清洗机也是世界公认科学、经济、的清洁方式之一。下面来讲讲高压去毛刺清洗机运行前后的各个问题排查。
High pressure deburring cleaning machine is one of the world recognized scientific, economic and environmental cleaning methods because it uses high pressure water column to clean dirt. Let's talk about the troubleshooting before and after the operation of the high-pressure deburring washer.
一、高压去毛刺清洗机在运行的过程中如果出现异常的尖叫声,大部分原因是由于电机轴承缺油导致的。这时我们只要在电机的注油孔注入普通黄油就可以,这种情况发生的不多。我们在高压去毛刺清洗机定期检修维护时给予补充就可以了。
1、 If abnormal squeal occurs during the operation of the high-pressure deburring washer, most of the reasons are due to the lack of oil in the motor bearing. At this time, we only need to inject ordinary butter into the oil injection hole of the motor to solve this problem, which rarely happens. We can supplement the high-pressure deburring cleaning machine for regular maintenance.
二、高压去毛刺清洗机在启动后,出现压力不稳定或时有时无,这里多数原因是高压水泵或进水管路内吸入了空气所导致的,这时需要检查水源的压力是否足够,进水过滤器是否堵塞,如果发现进水滤网堵塞,将滤网取下用水清洗就可以了。
2、 After the high-pressure deburring cleaning machine is started, the pressure is unstable or sometimes absent. Most of the reasons are caused by the intake of air in the high-pressure water pump or water inlet pipe. At this time, it is necessary to check whether the pressure of the water source is sufficient and whether the water inlet filter is blocked. If the water inlet filter screen is blocked, remove the filter screen and clean it with water.
三、高压去毛刺清洗机在运行的过程中有一定的工作压力但是调不到设备的额定压力或者说压力只停留在一定范围内而不能上升,在这种情况下,要判断高压喷嘴的孔径是否匹配。如更换高压喷嘴后压力仍然上不去,这时需要查看调压阀是否调到位了,如果在排除这两种情况下故障依旧,这说明泵内密封组件(水封)损坏或者是活塞损坏,这种情况需要联系厂商协助维修。
3、 The high-pressure deburring washer has a certain working pressure during operation, but cannot adjust to the rated pressure of the equipment, or the pressure only stays within a certain range and cannot rise. In this case, it is necessary to judge whether the aperture of the high-pressure nozzle matches. If the pressure still cannot rise after the high-pressure nozzle is replaced, check whether the pressure regulating valve is adjusted to its position. If the fault persists after the two conditions are eliminated, it means that the sealing component (water seal) in the pump is damaged or the piston is damaged. In this case, contact the manufacturer for assistance in maintenance.
高压去毛刺清洗机
四、高压去毛刺清洗机在正常运转一定时间后压力降低,这种情况要检查高压喷嘴是否严重磨损,普通压力设备的高压喷嘴基本上不会出现磨损现象,因为我们所配的高压喷嘴都进行过热处理。而高压设备的高压喷嘴就难以保证了。其次需要分别检查调压阀和水泵内部的密封组件。
4、 The pressure of the high-pressure deburring washer decreases after a certain period of normal operation. In this case, first check whether the high-pressure nozzle is seriously worn. The high-pressure nozzle of ordinary pressure equipment will not be worn basically, because the high-pressure nozzle we have equipped is subject to overheating treatment. The high-pressure nozzle of high-pressure equipment is difficult to guarantee. Secondly, check the pressure regulating valve and the sealing components inside the water pump respectively.
五、启动设备后,高压水泵没有水射出,这时需要厂商维修人员检查。大部分原因是进水流量阀不能打开造成的,如果排除这种情况下问题依旧,那就是高低压水路串联了,也就是说低压管路的水进不了高压管路,从而高压水泵无法工作。出现这种现象需要联系厂商协助维修。
5、 After the equipment is started, no water is ejected from the high-pressure water pump, which requires the manufacturer's maintenance personnel to check. Most of the reasons are that the inlet flow valve cannot be opened. If the problem still exists, the high and low pressure water circuits are connected in series, that is, the water in the low pressure pipeline cannot enter the high pressure pipeline, so the high pressure water pump cannot work. In case of this phenomenon, the manufacturer should be contacted to assist in maintenance and solution.
关于高压去毛刺清洗机运行前后的各个问题排查的相关内容就讲解到这里了,您对此有什么想咨询的内容就来我们网站看看吧!
This is all about the troubleshooting of various problems before and after the operation of the high-pressure deburring washer. If you have any questions about this, please visit our website at !